WEG manual for the POS2 programmable PLC card used with the SCA-05 servo drive: installation, parameter reference P750-P789 and error messages.
This manual from WEG describes the POS2 programmable card, which adds PLC (Programmable Logic Controller) functions to the SCA-05 servo drive so that interlocking programs can use the card's digital inputs and outputs as well as the drive's own digital and analog inputs and outputs. The card is programmed in Ladder language with the WLP software, and the document covers the software version V1.1X.
The manual is organized into safety instructions, general information about the card, installation and configuration, a quick reference of parameters P750 to P789, detailed parameter descriptions, and a list of error messages E50 to E67. It also explains how the card is installed in the servo drive, describes the connectors, gives the settings needed to configure the SCA-05 with the POS2 card, and mentions the general-purpose parameters P800 to P899 that the user can program through the WLP manual. This manual is written in Portuguese.
| Firmware version | V1.1X |
|---|---|
| Scan cycle (P751) | 0 to 65535, in units of 100 us |
| Encoder pulses (P768) | 0 to 65535, factory setting 1024 ppr |
| CAN address (P771) | 0 to 127, factory setting 63 |
| CAN baud rate (P772) | 1 Mbit/s, 500, 250, 125, 100, 50, 20 and 10 kbit/s |
It adds PLC (Programmable Logic Controller) functions, allowing interlocking programs that use the card's digital inputs and outputs and the drive's digital and analog inputs and outputs.
E50 is a lag error; it is a fatal error that disables the servo drive, and the manual refers to parameter P762.
The system must be restarted whenever one or more of the parameters marked with an asterisk is changed, so that it operates as programmed.