Pentair Aurora Model 653A vertical one-stage solids handling pump instruction and repair manual covering bearing lubrication and warranty terms.
The Pentair Aurora Model 653A is a vertical one stage solids handling pump. This instruction and repair manual includes a note asking the installer to provide the manual to the equipment owner or the party responsible for maintaining the system.
The document covers lubrication of regreasable bearings, including recommended grease, grease flushing, and lubrication intervals for dry and wet locations. It also contains a California Proposition 65 warning and the seller's warranty terms.
Chevron SRI Grease NLGI 2 (polyurea thickener) is recommended; most major brands of Grade No. 2 ball bearing grease are also satisfactory.
Lubricate at least every 4,000 hours of running time or every 6 to 12 months, whichever is more frequent.
Bearings need lubrication at least after every 2,000 hours of running time or every 4 to 6 months, whichever is more frequent.
Equipment is warranted for one year from installation or start-up, or eighteen months after shipment, whichever occurs first.