Pentair Aurora 653A Vertical One Stage Solids Handling Pump Instruction and Repair Manual

Pentair Aurora Model 653A vertical one-stage solids handling pump instruction and repair manual covering bearing lubrication and warranty terms.


Pentair Aurora 653A Vertical One Stage Solids Handling Pump Instruction and Repair Manual - cover page
Brand
Pentair
Document type
Service Manual
Language
English
Pages
12
File format
PDF
File size
1.3 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2CE4270D86D311B0D4B0250A58176361

About this manual

The Pentair Aurora Model 653A is a vertical one stage solids handling pump. This instruction and repair manual includes a note asking the installer to provide the manual to the equipment owner or the party responsible for maintaining the system.

The document covers lubrication of regreasable bearings, including recommended grease, grease flushing, and lubrication intervals for dry and wet locations. It also contains a California Proposition 65 warning and the seller's warranty terms.

What's inside

  • Lubrication of Bearings
  • California Proposition 65 Warning
  • Warranty
  • Performance
  • Liability Limitations
  • Acts of God
  • Compliance with Law

Frequently asked questions

What grease is recommended for the bearings?

Chevron SRI Grease NLGI 2 (polyurea thickener) is recommended; most major brands of Grade No. 2 ball bearing grease are also satisfactory.

How often should bearings be lubricated in dry locations?

Lubricate at least every 4,000 hours of running time or every 6 to 12 months, whichever is more frequent.

How often should bearings be lubricated in wet locations?

Bearings need lubrication at least after every 2,000 hours of running time or every 4 to 6 months, whichever is more frequent.

What is the warranty period?

Equipment is warranted for one year from installation or start-up, or eighteen months after shipment, whichever occurs first.