Pentair TS5L Linear Temperature Sensor Installation Guide

This document describes the temperature sensor used with Compool pool and spa control systems. This sensor can be used for water or solar applications and can also be used for freeze protection with the Cp3800 Control system family. The UY wire connectors are designed for 22-26 gauge wires and can be used indoors or outdoors.


Pentair TS5L Linear Temperature Sensor Installation Guide - cover page
Brand
Pentair
Category
Other
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
120 KB
Published
12 July, 2012
Updated
29 September, 2023
MD5 checksum
78510BB4C8FA95844893B6C949BFC5AC

About this manual

The Pentair TS5L is a linear temperature sensor designed for use with Compool pool and spa control systems. The kit includes one temperature sensor with a 25-foot cable and two UY wire splicing connectors. It is compatible with water or solar applications and, when used with the Cp3800 Control system family, can also provide freeze protection.

What's inside

  • Application
  • Kit Includes
  • Water Temperature Sensor Replacement
  • Solar Temperature Sensor
  • Freeze Temperature Sensor

Specifications

Cable Length25 feet
Wire Gauge22-26 guage
Connector TypeUY Wire Splicing Connectors
Compatible Control SystemsCp3800, Cp3600, Cp3400, Cp3810, Cp3820, Cp3830

Frequently asked questions

What applications is the TS5L sensor used for?

It is used for water or solar applications and can also be used for freeze protection with the Cp3800 Control system family.

How do I connect the sensor for water temperature?

Run the cable to the Power Center and connect the RED wire to the (+) terminal and the GREEN wire to the (-) terminal.

What is the correct wiring for the solar temperature sensor?

Connect the Sensor wires to the SOLAR screw terminals, with RED to (+) and GREEN to (-).