Metrix PRO440/6000 Vibration Switch Installation Manual

Installation, wiring, and configuration guide for the Metrix PRO440/6000 programmable vibration protection instrument.


Metrix PRO440/6000 Vibration Switch Installation Manual - cover page
Brand
Metrix
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
2.1 MB
Published
28 October, 2026
Updated
28 October, 2026
MD5 checksum
1163A1072D88ECA60FA07B9990E5FF16

About this manual

The Metrix PRO440/6000 is a versatile, programmable vibration protection instrument designed for industrial applications. It features a real-time remote operator interface via a membrane keypad or USB connection to a PC, allowing users to tailor the switch to specific monitoring needs. The device accepts most accelerometer or velocity inputs and can power a 4-20 mA loop-powered sensor to function as a field monitor.

What's inside

  • General Safety Summary
  • Installation Mechanical Housing
  • Wiring Power Connections
  • Connecting Alarm & Shutdown Relay Outputs
  • Connecting I/O Connections
  • Connecting Analog Output
  • Connecting Buffer Output
  • Connecting External Sensor
  • Configuration Using Optional Display
  • Power Up Sequence

Specifications

Power Supply (DC)22 to 26V DC
Power Supply (AC)85 to 265V AC, 50/60 Hz
Maximum Load per Relay10A
Max Mounting Surface Temperature185°F
Buffer Output Cable Capacitance0.02uF

Frequently asked questions

What types of sensors can be connected to the switch?

The switch can connect external accelerometers, piezo-electric velocity sensors, electromechanical velocity sensors, and 4-20mA transmitter inputs.

How is the bypass input connected?

Connect the bypass terminals to a remotely located NO (Normally Open) toggle switch to disable relays from entering alarm or shutdown states.

What happens to the analog output if the sensor is not OK?

In case of a malfunction like a sensor not being OK, the analog output drops to 3.6 mA.