This document provides installation and assembly instructions for the LAPP SKINTOP CLICK and CLICK-R cable glands, including technical specifications and…
This instruction sheet covers the SKINTOP CLICK and CLICK-R cable glands manufactured by LAPP. It details the protection classes (IP68) for various sizes, temperature ranges, and specific assembly steps for installation and disassembly. This manual is written in German.
| Protection class Ø12 | IP 68, 4bar (30min) |
|---|---|
| Protection class Ø16 - Ø25 | IP 68, 5bar (30min) |
| Protection class Ø32 | IP 68, 1bar (30min) |
| Dynamic temperature range | -20°C up to 100°C |
| Static temperature range | -40°C up to +100°C |
| UL File No. | E 79903 |
The holes in the housing must use a chamfer of 45°.
Hand screw the pressure nut counter clockwise to fasten the gland.
Open the latch system by pressing with both thumbs on the SKINTOP CLICK.