IAI PCON-C/CG/CF Controller Positioner Operation Manual

Seventeenth edition operation manual for the IAI PCON-C/CG/CF controller positioner, covering handling, structure, maintenance, wiring, and specifications.


IAI PCON-C/CG/CF Controller Positioner Operation Manual - cover page
Brand
iAi
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
226
File format
PDF
File size
5 MB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
037D6211C9493552ACE6B438FE7330CD

About this manual

This operation manual is the seventeenth edition for the IAI PCON-C, PCON-CG, and PCON-CF controller positioner. It explains handling methods, structure, maintenance, and other information needed to use the product safely.

The manual also covers initial parameter settings, wiring, specifications, and cautions such as use environment and backup of position data and parameters. The controller operates on 24 VDC, controls one axis, and has protection class IP20.

What's inside

  • Please Read Before Use
  • Changes to Zone Function
  • Use Environment
  • PC Software and Teaching Pendant Models
  • Recommendation for Backing up Latest Data
  • Initial Parameter Settings at Startup
  • Using a Rotary Actuator in Multi-rotation Specification
  • Specifications
  • Basic Specifications
  • Wiring

Specifications

Number of controlled axes1 axis/unit
Supply voltage24 VDC ±10%
Heat output (PCON-C/CG)9.6 W
Heat output (PCON-CF)26.4 W
Control methodWeak field-magnet vector control
Encoder resolutionIncremental specification, 800 Puls/rev
Number of positioning points64 (standard) to 512 (maximum)
Backup memoryPosition data and parameters saved in nonvolatile memory
Serial communicationRS485, 1 channel (Modbus protocol)
Electromagnetic-brake forced releaseNOM/BK RLS switch (front panel)
Actuator cable length20 m or less
I/O flat cable length5 m or less
Isolation strength500 VDC, 10 MΩ
Surrounding air temperature0 to 40°C
Surrounding humidity85%RH or less (non-condensing)
Storage temperature-10 to 65°C
Storage humidity90%RH or less (non-condensing)
Vibration resistance (10-57 Hz)Pulsating amplitude 0.035 mm continuous, 0.075 mm intermittent
Vibration resistance (57-150 Hz)4.9 m/s² continuous, 9.8 m/s²
Protection classIP20
Cooling methodNatural air cooling / Forced air cooling
Weight (PCON-C/CG)300 g or less
Weight (PCON-CF)320 g or less
External dimensions35 W x 175.5 H x 68.1 D mm
PIO interface24-VDC I/O
LED indicatorsSV (green) servo on; ALM (red) alarm present

Frequently asked questions

What supply voltage does the PCON-C/CG/CF controller require?

The controller requires a 24 VDC supply voltage with a tolerance of ±10%.

How many axes can one PCON-C/CG/CF unit control?

One unit controls one axis.

What is the protection class of the controller?

The controller has protection class IP20.

How many positioning points are supported?

The controller supports 64 positioning points in the standard configuration and up to 512 points maximum.

Download PDF (5 MB)

More iAi Manuals