This manual covers mechanical handling, installation, electrical setup, shielding, calibration, and troubleshooting for the FUTEK LSM Series tension and…
This document serves as a user manual for the FUTEK LSM Series load cells, which are designed as OEM components for space-saving applications. It provides essential guidelines on mechanical handling to prevent damage, including warnings against pulling the sensor by cables and avoiding excessive torque during installation. The text also details the importance of maintaining a clean environment and monitoring zero output during setup to avoid damage. This manual is written in Japanese.
| Maximum Bolt Tightening Torque (LSM200) | 25 in-lbs |
|---|---|
| Maximum Bolt Tightening Torque (LSM250) | 60 in-lbs |
| Maximum Applied Voltage (LSM250) | 18 V |
| Maximum Applied Voltage (LSM300) | 18 V |
| Maximum Applied Voltage (LSM302) | 18 V |
Annual calibration is recommended, though the inspection and calibration period is defined based on the application, conditions, durability, and usage method.
The cable shield must be grounded at one end, either at the sensor side or the equipment side, to avoid ground loops.
A shunt is an external resistor connected to two points of the load cell Wheatstone bridge to generate a known fixed output from the sensor.