Everlight application note on analog ambient light sensors, covering basic groups, RL/CL selection, and switch circuit design.
Everlight's application note covers analog ambient light sensors (ALS) that sense light similarly to the human eye for power-saving and safety applications. It describes four analog ALS groups and basic circuits for converting photo current to output voltage.
The note explains selecting load resistor RL and capacitor CL, including ripple reduction for fluorescent lighting, and discusses ADC-based and digital ALS options plus a non-symmetrical Schmitt trigger switch circuit.
Use 4.7uF for CL before selecting the right value for RL.
The recommended discharge time should be larger than 200ms.
Digital ALS is mentioned with 16 bits resolution.
It is recommended to change to a larger output photo current ALS model.