This datasheet covers the CTP-L1-AP-U-HA-AZ-SA-124225 (order no. 124225) transponder-coded safety switch CTP-AP with M12 plug connector. The switch combines guard locking with integrated evaluation electronics, short circuit monitoring, two semiconductor safety outputs, a door monitoring output and a diagnostic output, and reaches up to category 4/PL e according to EN ISO 13849-1. Guard locking is actuated by spring force and released by power (closed-circuit current principle), and the approach direction can be adjusted in 90° steps for directions A, B and C in the delivery state.
The document lists the 8-pin M12 connector assignment and conductor colors, a dimension drawing and wiring diagram, mechanical and electrical ratings, and reliability values. Each actuator is highly coded (unicode) and the switch detects only taught-in actuators, with only the last actuator taught-in being detected. A section on accessories lists bent, hinged and straight actuators, bolts, M12 connection cables in several lengths, emergency unlocking, handles, locks for the auxiliary release and a lockout mechanism.
| Housing material (safety switch housing) | Fiber glass reinforced thermoplastic |
|---|---|
| Net weight | 0,42 kg |
| Ambient temperature | -20 ... +55 °C at U = 24 V DC |
| Degree of protection | IP67/IP69/IP69K (screwed tight plug connector/mating component) |
| Switching frequency | max. 0,5 Hz |
| Connection | 1 plug connector M12, 8-pin |
| Approach speed | max. 20 m/min |
| Locking force Fmax | 3900 N |
| Locking force Fzh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
| Operating voltage DC | 24 V DC -15% ... 15%, PELV |
| Safety outputs FO1A / FO1B | 2 semiconductor outputs, p-switching, short circuit-proof |
| Switching current per safety output | 1 ... 150 mA |
| Discrepancy time | max. 10 ms for both safety outputs |
| Performance Level / Category | PL e, Category 4, PFH 4.1 x 10-9 |
| Mission time | 20 y |
| Solenoid duty cycle | 100 % |
It reaches up to category 4 and PL e according to EN ISO 13849-1, with reliability values of Category 4, PL e and PFH 4.1 x 10-9.
Each actuator is highly coded (unicode); the switch detects only taught-in actuators, and only the last actuator taught-in is detected.
It has two semiconductor safety outputs, FO1A on channel 1 and FO1B on channel 2, which are p-switching and short circuit-proof.
Guard locking is actuated by spring force and released by power, following the closed-circuit current principle.