NKK UB2 Series Thin Flat Button Switch User Manual

The document introduces the general specifications and other rated parameters of NKK Switches' UB2 series slim button switch L82 and illuminated button switch L83, including electrical capacity, contact resistance, insulation resistance, dielectric strength, mechanical life, electrical life, nominal operating force, etc. It also provides information on materials and coatings, environmental data, installation, handling, standards and certifications.


NKK UB2 Series Thin Flat Button Switch User Manual - cover page
Brand
NKK
Category
switch
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
1.2 MB
Published
07 January, 2012
Updated
29 September, 2023
Model
UB2
MD5 checksum
3778FDC868C216283B562A584F43A9F6

About this manual

The NKK UB2 series thin flat button switch manual provides detailed electrical and mechanical specifications, environmental limits, and certification information. It includes data on contact resistance, insulation strength, mechanical and electrical life, and operating forces for both single‑pole and double‑pole versions.

Installation guidelines cover mounting force, soldering methods, cleaning procedures, and optional accessories. The document also lists ordering codes, LED options, and printable areas for custom branding. This manual is written in Chinese.

What's inside

  • 规格
  • 标准和认证
  • 安装
  • 处理
  • LED 规格
  • 订购举例
  • 图例
  • 可选的附件
  • 环境数据

Specifications

Maximum current rating5 A at 125/250 V AC or 5 A at 30 V DC
Contact resistance (silver)max 50 mΩ
Contact resistance (gold)max 100 mΩ
Insulation resistance≥200 MΩ at 500 V DC
Insulation strength≥1 000 V AC between contacts for ≥1 min
Mechanical life (momentary type)≥1 000 000 operations
Electrical life (silver contacts)≥10 000 operations
Operating force (single‑pole)1.90 N
Operating force (double‑pole)2.55 N
TravelPre‑travel 0.067 in (1.7 mm), Over‑travel 0.024 in (0.6 mm), Total 0.091 in (2.3 mm)
Operating temperature range-25 °C to +50 °C

Frequently asked questions

What is the maximum current rating for the UB2 switch?

The UB2 switch is rated for 5 A at 125/250 V AC or 5 A at 30 V DC.

What are the contact resistance values for silver and gold contacts?

Silver contacts have a maximum resistance of 50 mΩ, while gold contacts have a maximum of 100 mΩ.

How many operations can the momentary type UB2 switch endure mechanically?

The momentary type is rated for at least 1 000 000 mechanical operations.

What temperature range can the UB2 switch operate in?

It can operate from –25 °C up to +50 °C.

Download PDF (1.2 MB)