Assembly instructions for the Amphenol PowerLok 8.0 1POS 180D single-core straight shielded plug, covering cable prep, crimping, assembly, and electrical tests.
This bilingual Chinese/English manual describes assembly of the Amphenol PowerLok 8.0 1POS 180D single-core straight plug in its shielded version. It lists the included parts, cable stripping dimensions, crimping steps, assembly sequence, and required electrical tests.
The manual also gives end-cap tightening torque, insulation resistance and dielectric withstand voltage test parameters, and an appendix with cable crimping reference data for 25, 35, and 50 mm² shielding cable. This manual is written in Chinese.
| End cap tightening torque | 10~12 N·m |
|---|---|
| Insulation resistance, cable to shell/HVIL | >500 MΩ at 1000 V DC for 5 s |
| Insulation resistance, HVIL to shell | >100 MΩ at 1000 V DC for 1 s |
| Dielectric withstand voltage, cable to shell/HVIL | 5000 V DC for 10 s, leakage <5 mA |
| Crimping height/width (25 mm² shielding cable) | 7.8±0.2 mm / 9.0±0.2 mm |
| Crimping height/width (35 mm² shielding cable) | 9.5±0.2 mm / 11.0±0.2 mm |
| Crimping height/width (50 mm² shielding cable) | 11.5±0.2 mm / 13.3±0.2 mm |
Tighten the end cap with a torque of 10~12 N·m.
The insulation resistance must be greater than 500 MΩ at 1000 V DC for 5 seconds.
The test requires 5000 V DC for 10 seconds with leakage current below 5 mA.
The listed retention force for 25 mm² shielding cable is 2000 N.