This document provides installation instructions for standard front-rack mounting the Dell W-7024/W-7205 controller in a standard two-post 19" Telco rack using the SPR-RK3-MNT accessory kit.
This document provides installation instructions for standard front-rack mounting the Dell W-7024/W-7205 controller in a standard two-post 19-inch Telco rack using the SPR-RK3-MNT accessory kit. The kit includes rack mount brackets, screws, cage nuts, clip nuts, and this printed installation guide.
The procedure covers attaching the mounting brackets to the device, inserting optional cage or clip nuts, and mounting the device in the rack. It also notes required tools, screw sizes, and minimum clearance around the controller for airflow and access.
| Rack type | Standard two-post 19-inch Telco rack |
|---|---|
| Included brackets | Two rack mount brackets |
| Included flat head screws | Eight M4 x 8 mm Phillips Flat Head screws |
| Included pan head screws | Four M6 x 15 mm Phillips Pan Head screws |
| Included cage nuts | Four M6 cage nuts |
| Included clip nuts | Four M6 clip nuts |
| Minimum side clearance | 10 cm (4 inches) |
Suitable screwdrivers are required and are not included in the kit.
Leave at least 10 cm (4 inches) on the left and right sides, plus additional space in front and back.
The figures show the W-7205 controller, but the same procedure applies to the W-7024 controller.
If the rack requires them, insert cage nuts or clip nuts on the front rails.