WEG SSM5-30R / SSM5-40R Magnetic Sensor for Safety Applications Installation Guide

The SSM5 is intended for applications where you wish to monitor grids, doors, gates and the like. For safety applications with the SSM5, we recommend interconnection with WEG CPA-D or CP-D safety relays or another relay of the same safety level (PLe, SIL3) and actuation with the ASSM5 coded actuator to avoid possible failures. The SSM5 has two outputs.


WEG SSM5-30R / SSM5-40R Magnetic Sensor for Safety Applications Installation Guide - cover page
Brand
WEG
Category
sensor
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
2.6 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
B2B6018373C7BAB511FDA326C289FFF8

About this manual

The SSM5-30R and SSM5-40R are magnetic sensors for safety applications used to monitor grids, doors, gates and similar equipment. The guide covers safety instructions, general information, operation, technical characteristics, function diagrams, connections, dimensions and certification.

The sensor has two outputs that must be wired individually and is intended for use with WEG CPA-D or CP-D safety relays or an equivalent safety relay, plus the ASSM5 coded actuator, to reach PLe/SIL3. Its technical data include a 5 mm operating distance, IP67 protection and an ambient temperature range of -25 C to +70 C.

What's inside

  • Safety instructions
  • General information
  • Operation description
  • Technical characteristics
  • Function - P2A
  • Function - P201
  • Connections
  • Dimensions
  • Certification

Specifications

Switching voltage5 to 60 Vdc or 5 to 25 Vac
OutputNO dual channel NO
Contact capacity100 mA - 3 W
NC auxiliary contact capacity10 mA
Operating distance5 mm +/-10% (maximum)
Maximum switch on distance6 mm +/-10% (maximum)
Maximum switch off distance10 mm +/-10% (maximum)
Electrical life107 operations
Protection ratingIP67
Housing materialPolyamide - PA
Ambient temperature-25 C to +70 C (-13 F to 158 F)
Storage/transportation temperature-25 C to +70 C (-13 F to 158 F)
Maximum switching frequency10 Hz
Shock resistance30 g/11 ms
Vibration resistance10 a 55 Hz (1 mm amplitude)
Actuation modeMagnetic transmission
Wiring typePVC cable or M8 connector
Connector versionP2A; M8 / 4 way on request
MountingWith screws
StandardsIEC 60947-5-1, IEC 60947-5-2, IEC 60204, IEC 62061 SIL3, IEC ISO 13849-1 PLe, NBR 14.153, 2006/42/CE

Frequently asked questions

Which safety relays are recommended for use with the SSM5?

WEG CPA-D or CP-D safety relays, or another relay with the same safety level (PLe, SIL3).

Which actuator is used with the SSM5?

The ASSM5 coded actuator.

What is the operating distance of the sensor?

5 mm +/-10% (maximum).

What protection rating does the housing have?

IP67.