YASKAWA Varispeed L7 INSTRUCTION MANUAL, Model: CIMR-L7C
Yaskawa Varispeed L7 is an inverter for lift applications, with 200 V class and 400 V class models rated from 3.7 to 55 kW. This instruction manual covers installation, wiring, user constants, trial operation, maintenance, safety precautions, and EMC compatibility.
The manual states safety warnings for installation, wiring, operation, and maintenance, including grounding requirements and a 5-minute wait for capacitor discharge after power is disconnected. It also describes EMC installation methods and lists revision history.
| 200 V class power range | 3.7 to 55 kW (7 to 98 kVA) |
|---|---|
| 400 V class power range | 3.7 to 55 kW (7 to 106 kVA) |
| Grounding resistance | 200 V class: 100 Ω or less; 400 V class: 10 Ω or less |
| Cooling air temperature | Below 45°C for air entering inverters |
| EMC standard | EN61800-3 |
| Capacitor discharge wait | 5 minutes after disconnecting power |
It covers 200 V class and 400 V class units from 3.7 to 55 kW.
Wait 5 minutes for capacitor discharge after disconnecting the power supply.
Ground to 100 Ω or less for 200 V class and 10 Ω or less for 400 V class.
Do not change the factory setting (0) in b1-03 (Run Command source selection).