Yaskawa Varispeed L7 is an inverter for lift applications, with 200 V class and 400 V class models rated from 3.7 to 55 kW. This instruction manual covers installation, wiring, user constants, trial operation, maintenance, safety precautions, and EMC compatibility.

The manual states safety warnings for installation, wiring, operation, and maintenance, including grounding requirements and a 5-minute wait for capacitor discharge after power is disconnected. It also describes EMC installation methods and lists revision history.

What's inside

  • Preface
  • Safety Information
  • Safety Precautions
  • Confirmations upon Delivery
  • Installation
  • Wiring
  • Setting User Constants
  • Trial Operation
  • Maintenance and Inspection
  • EMC Compatibility

Specifications

200 V class power range3.7 to 55 kW (7 to 98 kVA)
400 V class power range3.7 to 55 kW (7 to 106 kVA)
Grounding resistance200 V class: 100 Ω or less; 400 V class: 10 Ω or less
Cooling air temperatureBelow 45°C for air entering inverters
EMC standardEN61800-3
Capacitor discharge wait5 minutes after disconnecting power

Frequently asked questions

What power and voltage classes does the Varispeed L7 inverter cover?

It covers 200 V class and 400 V class units from 3.7 to 55 kW.

How long must I wait after turning off power before maintenance?

Wait 5 minutes for capacitor discharge after disconnecting the power supply.

What grounding resistance is required?

Ground to 100 Ω or less for 200 V class and 10 Ω or less for 400 V class.

Which user constant must not be changed from its factory setting?

Do not change the factory setting (0) in b1-03 (Run Command source selection).