The TLY25 is a microprocessor digital electronic controller for refrigeration. It features: - Easy programming and operation - A variety of functions, including set point programming, password protected programming, parameter programming, time scheduling, panel mounting, initial installation, mounting layout, electrical connections, configuration mapping, configuration, keyboard configuration parameters, etc.
This is the Portuguese instruction manual (November 2012, document B14 9225 156 rev.2) for the TLY25, a microprocessor-based digital electronic controller developed for refrigeration applications with temperature and defrost control. The process temperature is shown on a 4-digit red display, and LEDs next to the display indicate the state of the outputs. The instrument has up to four configurable relay outputs for compressor (OUT), defrost (DEF), fan (FAN), auxiliary output (AUX) and alarm, two inputs for NTC or PTC probes, and one configurable digital input.
The 18-page manual explains the front-panel keys and LEDs, how to program the Set Point and the parameter groups (with optional password protection and an internal real-time clock for defrost), panel mounting and multiple-unit arrangement, and the electrical connections. It also covers configuration with the KEY-01 copy key, error indications and other troubleshooting information, technical data, output configuration suggestions, dimensions, the electrical diagram and ordering information. This manual is written in Portuguese.
| Display | 1 red 4-digit display |
|---|---|
| Relay outputs | Up to 4 configurable relay outputs (OUT, DEF, FAN, AUX/alarm) |
| Probe inputs | 2 inputs for NTC or PTC probes (room temperature and evaporator) |
| Digital input | 1 configurable digital input |
| Clock power reserve | 4 hours |
| Programming protection | Password protection of configuration parameters |
| Configuration device | KEY-01 (Copy Key) |
Press the confirm key, or do not press any key for 20 seconds and the instrument leaves the Set Point programming mode.
The clock keeps running on a four-hour power reserve.
The controller accepts NTC or PTC probes on two inputs, one for room temperature control and one for monitoring the evaporator temperature.
Keep the key pressed while powering the instrument on; the display then shows the code of the first parameter group (SP).