Baumer FS218 FS219 Electromechanical Preset Counter Data Sheet

This product is a large pulse counter with one preset, subtracting function, 5-digit display, manual and electric reset.


Baumer FS218 FS219 Electromechanical Preset Counter Data Sheet - cover page
Brand
Baumer
Category
Counter
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
194 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
507E83C6F5191765CEB90472DBCC34C9

About this manual

This four-page Baumer data sheet covers the FS218 and FS219 electromechanical preset counters. Both models have a 5-digit display with 8 mm digit height, one preset, a subtracting count mode where 1 impulse = 1 count, and a measuring range of 99 999. They are built into a front panel with four screws and connect through a 10-pin plug-in terminal connector.

The document lists electrical ratings (24/110 VAC, 230 VAC and 24 VDC supplies, 1:1 pulse ratio, 100 million impulses service life, change-over output contact by micro-switch), mechanical data (Hostaform POM black housing, 144 x 72 x 129 mm, IP 41), connection diagrams, ordering part numbers for voltage and reset variants, and the Z 100.04A front panel accessory with transparent protective cover.

What's inside

  • Features
  • Technical data - electrical ratings
  • Technical data - mechanical design
  • Connection diagram
  • Accessories
  • Part number
  • Dimensions

Specifications

Voltage supply24/110 VAC ±10 % (50/60 Hz), 230 VAC +6/-10 % (50/60 Hz), 24 VDC ±10 %
Number of digits5 digits
Digit height8 mm
Measuring range99 999
Count mode1 impulse = 1 count, subtracting in 2 half steps
Service life100 million impulses
Switching current2 A (VAC), 1 A (VDC)
ProtectionIP 41 per DIN EN 60529
Ambient temperature-5...+50 °C
Dimensions W x H x L144 x 72 x 129 mm
Cutout dimensions113 x 61 mm (+0.5)
Weightapprox. 650 g (FS218), approx. 850 g (FS219)
MountingFront panel with 4 screws
ConnectionPlug-in terminal connector, 10-pin

Frequently asked questions

What is the difference between the FS218 and the FS219?

The FS218 is reset manually by a button to preset, while the FS219 has both a button reset and an electrical reset.

Which supply voltages can be ordered?

The part number table lists 24 VDC, 24 VAC, 110 VAC and 230 VAC voltage variants.

How is the counter mounted?

It is mounted in a front panel with 4 screws, using a 113 x 61 mm cutout.

What counting range does the display have?

The 5-digit display has a measuring range of 99 999, counting in a subtracting mode.