About this manual

This instruction manual for the Panasonic Electric Works SUNX FX-100 Series fiber optic digital sensor is written in Spanish. It gives warning notes on using the sensor, lists precautions for wiring, power supply, noise and environment, and describes the parts of the amplifier: output indicator, mode key, ON/increase key, OFF/decrease key, green digital display for the threshold value and red digital display for received light intensity.

The manual then explains mounting on a 35 mm DIN rail or with M3 screws and nuts at no more than 0.5 N·m, and how to connect the fiber cable using the fiber lock lever, including a note on coaxial reflective fibers such as FD-G4 or FD-FM2. The product is described as intended for industrial use only.

What's inside

  • Precautions
  • Description of Parts
  • Mounting on a DIN Rail
  • Mounting with Screws and Nuts
  • Connecting the Fiber Cable
  • Warning Notes

Specifications

Maximum cable extension100 m with cable of 0.3 mm² or larger
DIN rail width35 mm
Mounting screw sizeM3 screws with nuts
Maximum tightening torque0.5 N·m
EEPROM learning limit100,000 times
Start-up transient time0.5 s

Frequently asked questions

How far can the sensor cable be extended?

The cable can be extended up to 100 m using a cable of 0.3 mm² or larger, and should be kept as short as possible to reduce noise effects.

What tightening torque should be used when mounting with screws?

Use M3 screws with nuts and do not apply more than 0.5 N·m so that the housing is not broken.

Can this sensor be used outdoors?

No. The manual states that the product must not be used outdoors.

Can the sensor be used as a safety sensor to protect people?

No. It must never be used as a safety sensor for protecting persons; products that comply with standards such as OSHA, ANSI or IEC must be used instead.