Datalogic S50-Px Series Sensor Instruction Manual

The S50-Px series of sensors uses innovative optical technology to detect a wide range of objects, including transparent and semi-transparent objects. The series includes a variety of models to meet different application needs.


Datalogic S50-Px Series Sensor Instruction Manual - cover page
Brand
Datalogic
Category
sensor
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
117 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
35D4BFE3FF1FD8FD5079F063F8A9031F

About this manual

Instruction manual for the Datalogic S50-Px Series sensors, covering the axial (S50-PA) and radial (S50-PR) versions and their variants. It explains the meaning of the output LED, stability LED and power on LED, describes how the sensitivity trimmer is used, and gives installation instructions for the M18x1 threaded body or the two housing holes, together with the available fixing accessories.

Further sections cover the electrical connections (including the M12 4-pole connector and the TEST inputs on the G00 model), outline dimensions for the axial, radial, cable and fibre optic versions, a full technical data table, and step-by-step setting procedures for the A00, B01/T01, F01/G00/E01, C01/C21/E01 and C10/D00 models. The document also lists the Datalogic contact details, warranty period and disposal information.

What's inside

  • Controls: output LED, stability LED, power on LED, trimmer
  • Installation
  • Connections
  • Dimensions (axial, radial, cable, fibre optic versions)
  • Technical data
  • Setting of S50-Px…A00
  • Setting of S50-Px…B01/T01
  • Setting of S50-Px…F01/G00/E01 with OF-43
  • Setting of S50-Px…C01/C21/E01 with OF-42
  • Setting of S50-Px…C10/D00

Specifications

Power supply10 … 30 Vdc (limit values)
Ripple2 Vpp max.
Current consumption (output current excluded)35 mA max.
OutputsNO and NC; PNP or NPN (short-circuit protection)
Output current100 mA max.
Response time0.5 ms (2 ms mod. F01/G00)
Switching frequency1 kHz (250 Hz mod. F01/G00)
Operating temperature-25 … 55 °C
Storage temperature-25 … 70 °C
Housing materialPBT
Lens materialPMMA
Mechanical protectionIP67
Weight75 g max. cable version / 25 g max. connector version
Insulating strength500 Vac 1 min., between electronics and housing
Connections2 m cable 4 mm / M12 - 4 pole connector

Frequently asked questions

What is the supply voltage of the S50-Px Series sensor?

The sensor operates from a 10 … 30 Vdc power supply, with a maximum ripple of 2 Vpp.

How do I adjust the sensitivity of the sensor?

The sensitivity is adjusted with the trimmer; the operating distance increases when the trimmer is turned clockwise. Trimmer rotation is limited to 270° by a mechanical stop.

How is the S50-Px Series sensor installed?

It can be fixed by its M18x1 threaded body through an 18 mm hole using the enclosed washer and two CH.24 nuts, or through the two housing holes with two M3x22 or longer screws and washer.

What is the response time and switching frequency?

The response time is 0.5 ms and the switching frequency is 1 kHz, except for the F01/G00 models which have 2 ms and 250 Hz.

Download PDF (117 KB)

More Datalogic Manuals