The document describes the features and performance of the KEYENCE fiber optic sensor FS-V series, including dual digital display/bar LED/two-color display, standard single output/dual output/analog output, and expansion connection to reduce wiring.
This catalog excerpt presents the KEYENCE FS-V Series 1-line system fibre optic sensor amplifiers, covering the FS-V20 Series (FS-V21/V22), FS-V10 Series (FS-V11/V12/V10) and FS-V1. It describes the lineup with dual digital display, bar LED monitor and two-colour display options, standard single, dual and analogue output types, and NPN or PNP models with red, green or infrared (950 nm) LED light sources.
The document explains that the series uses a dedicated parallel operation chip (FALCON) instead of a general-purpose CPU, and that main units can be combined with up to 16 expansion units to reduce wiring. Detailed specification tables list response times, control and monitor outputs, timer functions, power supply, and environmental ratings for each amplifier type.
| Response time (FS-V20 Series) | 250 μs (FINE) to 50 μs (HIGH SPEED) depending on mode |
|---|---|
| Power supply | 12 to 24 VDC ±10%, ripple 10% max., Class 2 |
| Control output (NPN) | NPN open-collector 100 mA max. (40 VDC max.), residual voltage 1 V max. |
| Monitor output | Voltage output 1 to 5 V, load resistance 10 kΩ min., repeatability ±0.5% of F.S. |
| Number of expansion units | Up to 16 expansion units (17 units total) |
| Ambient temperature | -10 to +55°C, no freezing |
| Ambient humidity | 35 to 85%, no condensation |
| Housing / size | Polycarbonate, 30 mm (H) x 9 mm (W) x 70 mm (D) |
| Weight | Approx. 80 g (main unit), approx. 45 g (expansion unit), including 2-m cable |
| Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in X, Y and Z axes |
| Shock resistance | 500 m/s² in X, Y and Z directions, 3 times each |
Up to 16 expansion units can be connected to a single main unit, for a total of 17 units.
It operates on 12 to 24 VDC ±10% with a maximum ripple of 10% (Class 2).
It ranges from 250 μs in FINE mode to 50 μs in HIGH SPEED mode, with intermediate settings such as TURBO, SUPER TURBO, ULTRA TURBO and HIGH RESOLUTION.
The rated ambient temperature is -10 to +55°C with no freezing; when multiple units are mounted together the range is reduced (e.g. -10 to 50°C for 3 to 10 units).