MTA50000AB permanent magnet synchronous gearless traction motor user manual, which introduces the installation, debugging, use, maintenance and other contents of the traction motor
This Chinese user manual covers the MTA50000AB permanent magnet synchronous gearless traction motor, an elevator traction machine made up of a permanent magnet synchronous motor, a traction sheave, an encoder for speed/position feedback and a brake. It describes the machine's working conditions, protection rating, model specifications, outline and mounting dimensions, and the spare parts available to users.
The manual gives instructions for transport, storage and lifting, pre-installation checks, mounting, the remote manual brake release device, electrical connection, encoder types (ERN1387, Huitong, Tamagawa, Hengstler), brake installation and adjustment, and the manual emergency winding switch. It closes with maintenance intervals for the motor, brake and traction sheave, and a table of common faults with causes and remedies. This manual is written in Chinese.
| Protection rating | IP40 |
|---|---|
| Insulation class | Class F |
| Maximum altitude | 1000 m |
| Ambient temperature | 5 °C to 40 °C |
| Relative humidity | Not more than 90 % |
| Supply voltage tolerance | ±7 % of rated value |
| Insulation resistance to ground | At least 1 MΩ (500 V megger) |
| Frame surface flatness deviation | Maximum 0.1 mm |
| Brake operating gap | 0.3 mm to 0.4 mm |
| Brake gap when readjusted | 0.35 mm |
| Friction plate replacement threshold | Below 1 mm thickness |
| Brake damper replacement | After more than 2 million operations |
Altitude must not exceed 1000 m, ambient temperature must stay between 5 °C and 40 °C with relative humidity no more than 90 %, and the supply voltage may deviate no more than ±7 % from the rated value.
The traction motor has protection rating IP40 and insulation class F.
The normal working gap is 0.3 mm to 0.4 mm; when maintenance or repair requires adjustment, the gap should be set to 0.35 mm.
The brake should be inspected about every six months, and braking force should be tested at least every six months at 150 % of rated car load for 10 minutes without slipping.