This document is the user manual of 9452/9454 series products, which provides detailed parameters, installation methods, and usage methods of the products.
This 8-page installation and user guide covers the 9452 and 9454 dual-technology detectors, which combine passive infrared (IR) and microwave (MW) detection. It starts with the technical characteristics: a 12 m detection length, 24.125 GHz microwave frequency, DSP microprocessor technology, 10-15 Vcc power supply and a maximum consumption of 25 mA. The two articles differ only in cover color, 9452 white and 9454 brown.
The rest of the guide describes mounting with the angular or wall bracket, the wiring clamps (12V, GND, AMK antimasking, AS tamper, MEM inhibition/memory and AL alarm), the IR and MW range trimmers, the SW1 DIP switch and the JP1 jumper for internal or external setup. It also explains the LED indications for IR, MW, alarm and antimask events, the stabilization/acknowledging phase after power-up, and the AND, OR, MW antimask and IR antimask detection options.
| Detection length | 12 m |
|---|---|
| Microwave frequency | 24.125 GHz |
| Horizontal detection area | IR = 7.5°, MW = 32° |
| Vertical detection area | IR = 90°, MW = 80° |
| Installation height | 2.1 m (wall or window mount) |
| Power supply | 10-15 Vcc |
| Maximum consumption | 25 mA |
| Minimum consumption | 11 mA |
| Alarm relay time | 5 sec commutation |
| Antimasking relay time | 5 sec commutation after 25 sec of masking time |
| Tamper relay | Open relay when cover removed |
| Cover color | 9452 white, 9454 brown |
| Dimensions | 37 x 125 x 40 mm |
They differ in cover color: the 9452 has a white cover and the 9454 has a brown cover.
When MW antimask is enabled, the AMK output activates if an obstacle remains in front of the detector for about 25 seconds.
In AND mode the detector alarms only when both MW and IR are in pre-alarm; in OR mode it alarms when either MW or IR is in pre-alarm.
JP1 plugged in sets the detector for external use with more stability and more power consumption; plugged out it is set for internal use with more sensitivity and less power consumption.