Installation and programming manual for the C&K Active 5 intruder alarm panel, covering wiring, factory defaults, programming options and specifications.
The Active 5 is a microprocessor-controlled intruder alarm panel with five programmable zones. Programming options are held in non-volatile memory and retained after a total power failure, and up to three remote keypads can be used on the system.
The manual covers system planning, factory defaults, software revision V3.0 specifications, mounting and wiring, remote keypad connection, setting options, alarm outputs, initial power up and programming options. It is intended for engineers installing and programming the panel.
| Mains supply voltage | 230 v AC Nom |
|---|---|
| PSU output voltage | 13.6 v DC Nom |
| Maximum output current | 1 amp (total) |
| Aux current | 500 mA Max. |
| Operating temperature | 10 to 50 degrees centigrade |
| Humidity | Up to 80% non condensing |
| Dimensions | 304 mm (W) 220 mm (H) 89 mm (D) |
| Control panel weight | 1.45 kg Excluding Batt |
| Standby battery | 2.6 Ah 12 v Rechargeable 6 Ah max. |
| Maximum cable run | 100 Metres |
The Active 5 has five zones, all of which are programmable.
Up to three remote keypads can be used on the system.
The default user/customer code is 1234 and the default engineer code is 7890.
That zone will automatically be isolated to prevent repeated false alarms.