Schlage 101+ Series Delayed Egress Magnetic Locking System Installation and Programming Manual

Installation and programming manual for the Schlage 101+ delayed egress magnetic locking system, covering setup, wiring, programming and troubleshooting.


Schlage 101+ Series Delayed Egress Magnetic Locking System Installation and Programming Manual - cover page
Brand
Schlage
Category
Anti-Theft Devices
Document type
Installation Guide
Language
English
Pages
20
File format
PDF
File size
505 KB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
1D2FAB2F5A43FC0181F1B3AC42D257A9

About this manual

This manual covers the Schlage 101+, 101-2+ and 101DB delayed egress magnetic locking systems, including mechanical installation, wiring, dipswitch settings and terminal functions. It also provides technical specifications, programming instructions, error codes, troubleshooting and maintenance information.

The manual describes options such as ATR, BOCA, DSM, MBS, MX500, PWM and SEC, and instructs the installer to retain it for programming, maintenance and troubleshooting.

What's inside

  • Technical Specifications
  • Pre-Installation Considerations
  • Mechanical Installation
  • Dipswitch Settings
  • Wiring Information
  • Relock Time Delay
  • Keypad Manual Programming
  • Error Codes
  • Trouble Shooting
  • Maintenance

Specifications

Input voltage, standard models12 or 24 V AC or DC, automatic selection
Maximum current, standard models0.8 A at 12 V DC; 0.5 A at 24 V DC
Mechanical holding force1500 pounds
Audible output91 dB at 2 feet
PWM model holding force1200 pounds
Maximum current, 101-2+ and 101+DB models0.8 A total for both magnets at 12 V DC only

Frequently asked questions

What models does the manual cover?

The manual covers the 101+, 101-2+ and 101DB delayed egress magnetic locking systems. The 101-2+ is the double-door model with master and slave units.

What is the delayed egress delay time?

The delay time is generally fixed at 15 seconds, but with approval from the local authority having jurisdiction it can be set to 30 seconds on the standard unit.

What range can the nuisance delay be set to?

On the standard unit the nuisance delay can be set from 0 to 3 seconds. The BOCA unit is fixed at 1 second.

How many codes can the lock hold?

With optional SelectEntry keypads or TouchEntry Key readers, the locks can hold up to 150 codes standard for access, toggle, lockout or special function keys.