Balluff BF-IDM21 / BF-IDM09 RFID Reader Operating Guide

This document is about the operating guide for the BF-IDM21 and BF-IDM09 RFID readers. It introduces the functions and characteristics of the readers, installation and usage methods, and troubleshooting.


Balluff BF-IDM21 / BF-IDM09 RFID Reader Operating Guide - cover page
Brand
Balluff
Category
sensor
Document type
User Manual
Language
English
Pages
7
File format
PDF
File size
473 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
AB2331857F7AAA94851BA506B3C610F9

About this manual

The Balluff BF-IDM21 is an RFID reader intended to read and write ISO 15693 / ISO 14443 compliant data carriers via magnetic field communication. The readers operate in combination with BIS V processor units when connected to one of the ports labeled "H1" to "H4", using a shielded standard type 4-wire cable, M12 / A-coded. BF-IDM21 readers are available in different housings and shapes.

This operating guide covers the regulatory information, the purpose of the device, connection of the device including grounding notes, installation notes with examples of direct in-hole mounting, direct on-wall mounting and indirect on-wall mounting using a metal holder, status indicators, and the electrical and mechanical data of the reader.

What's inside

  • Regulatory Information
  • Purpose of the Device
  • Variability
  • Connecting the Device
  • Installation notes
  • Direct In-Hole mounting
  • Direct On-Wall mounting
  • Indirect On-Wall mounting using metal holder
  • Setup and Operation
  • Status Indicators

Specifications

Operating voltage (nominal)+24 V DC
Current draw (at +24 V DC)200 mA
Operating frequency13.56 MHz
Active principleMagnetic field
Maximum transmit power1 W
Housing materialMetal / ABS-GF16 / PBT / PA12-GF30
Weightmax. 400 g
Ambient temperature0...+70 °C

Frequently asked questions

How does the BF-IDM21 RFID reader communicate with data carriers?

It reads and writes ISO 15693 / ISO 14443 compliant data carriers via magnetic field communication.

What processor unit is needed to operate the BF-IDM21?

A BIS V type processor unit is needed; the reader connects to one of the ports labeled "H1" to "H4" with a shielded standard type 4-wire cable, M12 / A-coded.

What does the green Power LED indicate?

The green "Power" light indicates that the device is connected to the processor unit and ready to operate.

What does the orange LED indicate?

The orange "Tag present" light indicates that an RFID tag has been detected in front of the transceiver coil.

Download PDF (473 KB)

More Balluff Manuals