This is a user manual of micropulse transducer, which mainly introduces the function, installation connection, electrical connection, startup and use, technical data of the transducer.
Balluff's BTL7-V50T-M _ _ _ _ -P-C003 is a Micropulse Transducer in a profile housing with a PROFINET interface. It contains an aluminum housing with the waveguide and processing electronics; a magnet that moves along the waveguide defines the position to be measured.
The guide covers notes to the user, safety, construction and function, LED displays, installation and connection, startup, technical data, accessories, type code breakdown, and appendix. It is intended for qualified technical personnel and describes installation and startup only by trained specialists with basic electrical knowledge.
| Interface | PROFINET |
|---|---|
| Nominal length | 50 mm to 7620 mm |
| Maximum number of magnets | 16 |
| PROFINET cycle time with IRT | from 2 ms |
| Minimum distance between magnets | 65 mm |
| Housing material | Aluminum |
| Maximum tightening torque | 2 Nm |
| Encoder profile | PNO encoder profile V4.1 |
The guide states it forms a position measuring system together with a machine controller such as a PLC.
It can detect and process up to 16 magnets; the maximum number depends on the nominal length.
Red LED 1 indicates an error: no magnet or magnet outside the limits.
The distance between magnets must be at least 65 mm.