Thermo Scientific MSQ Plus Mass Detector Getting Started Guide

MSQ Plus Mass Detector Getting Started Guide


Thermo Scientific MSQ Plus Mass Detector Getting Started Guide - cover page
Brand
Thermo Scientific
Category
Analyzer
Document type
User Manual
Language
English
Pages
128
File format
PDF
File size
4.4 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
76606091EED65BDDD34D875525A56189

About this manual

This Getting Started Guide for the Thermo Scientific MSQ Plus Mass Detector, Revision A dated September 2013, introduces the instrument and explains how to configure an LC/MS system built around it. The opening chapters cover electrospray (ESI) and atmospheric pressure chemical ionization (APCI), how to introduce samples, what buffers can be used, calibration and parameter optimization, and instrument control methods.

The later chapters describe checking the hardware and the oil level in the oil mist filter and forepump, preparing and calibrating the mass detector, manual tuning in ESI and APCI modes, and creating instrument methods and sequences using the method editor, chromatogram view and sequence setup windows.

What's inside

  • Electrospray (ESI)
  • Atmospheric Pressure Chemical Ionization (APCI)
  • Configuring the Mass Detector
  • Configuring the LC System
  • Checking the Hardware
  • Checking the Oil Level in the Oil Mist Filter and the Forepump
  • Calibrating the MSQ Plus Mass Detector
  • Manual Tuning in ESI Mode
  • Manual Tuning in the APCI Mode
  • Creating Instrument Methods

Specifications

Software versionMSQ Plus Mass Detector 2.0 or later; Xcalibur 2.2 SP1 or later
Low-voltage safety standardEN 61010-1: 2001 with Corrigendum No. 1 and 2
EMC standardEN 61326-1 (1998)
FCC classificationCode of Federal Regulations, Part 15, Subpart B, Class A

Frequently asked questions

What software does the MSQ Plus Mass Detector require?

The guide lists the software version as MSQ Plus Mass Detector 2.0 or later, with Xcalibur 2.2 SP1 or later.

How many people are needed to lift or move the instrument?

The instrument is too heavy and/or bulky for one person alone, so lifting and moving it requires a team effort.

Can I use a mobile phone near the instrument?

No. The instrument is designed to work in a controlled electromagnetic environment, so radio frequency transmitters such as mobile phones should not be used close to it.

Is the MSQ Plus Mass Detector intended for diagnostic use?

No. It is for research use only and is not for use in diagnostic procedures.