Key facts
- Manuals
- 17
- Languages
- ZH · EN
- Last added
- 2026-10-03
Featured Thermo Scientific manuals

Thermo Scientific 8000WJ Series CO2 Incubator Operation and Maintenance Manual
The manual begins with safety warnings and a preface that stresses the need for qualified personnel to perform internal calibration and maintenance. It describes the physical components of the water‑jacket CO₂ incubator, including the heating door, gas sampling port, control panel, water‑jacket fill and drain ports, and leveling feet.
Subsequent sections cover step‑by‑step installation, startup procedures, detailed calibration of temperature, CO₂, O₂ and humidity sensors, configuration of alarm limits, routine cleaning, part replacement (fuses, filters, sensors), and a full specification table for electrical and environmental performance. This manual is written in Chinese.
Covers: Installation and Startup · Control Panel Operation · Calibration Procedures · Alarm Settings · Routine Maintenance · Part Replacement

Thermo Scientific Multiskan SkyHigh User Manual
The Thermo Scientific Multiskan SkyHigh is a microplate photometer for 6‑, 24‑, 96‑ and 384‑well plates, with optional color cup and touch‑screen models. This manual provides detailed instructions for installing the instrument, connecting it to a computer, and using the SkanIt software for data acquisition and analysis.
Safety guidelines, environmental specifications, power requirements, and a comprehensive maintenance checklist are included to ensure reliable, long‑term operation in laboratory settings. This manual is written in Chinese.
Covers: Introduction · Instrument Layout · Operating Principle · Installation of Multiskan SkyHigh · Installation of SkanIt Software · Instrument Operation

Thermo Scientific POPs Overall Analysis Workflow Product Leaflet
The POPs overall analysis workflow provides a complete solution for screening and confirming persistent organic pollutants in food, feed and environmental samples. It integrates dedicated instruments (TSQ Quantum XLS, DFS), specialized software (TargetQuan, SampleManager LIMS) and a centralized data‑management system to ensure high performance and regulatory compliance.
The workflow supports high‑throughput GC‑MS/MS screening with selective SRM capabilities and high‑resolution GC‑HRMS confirmation. It offers low detection limits (20 fg/µL for TCDD) and robust QA/QC features, enabling laboratories to meet stringent EPA, EU and JIS requirements while maintaining productivity. This manual is written in Chinese.
Covers: Analysis Workflow Overview · Screening Tools and Instruments · High‑Throughput GC‑MS/MS Screening · High‑Resolution GC‑HRMS Confirmation · TargetQuan Software and LIMS · Detection Limits and Precision

Thermo Scientific AquaClear Low-Range Turbidity Analyzer Product Leaflet
The AquaClear low‑range turbidity analyzer from Thermo Scientific is designed for high‑precision, low‑cost turbidity monitoring in drinking water, membrane processes, bottled water and other water‑quality applications. Its compact 135 mL flow cell removes bubbles and provides stable readings with a long‑life white‑light source.
The leaflet includes technical parameters, optional accessories, ordering codes and typical industry applications such as municipal water, industrial pure water, and wastewater monitoring. This manual is written in Chinese.
Covers: 仪器特点 · 技术参数 · 订购信息 · 市场/ 应用 · 行业应用方案
Latest Thermo Scientific manuals
Thermo Scientific 8000WJ Series CO2 Incubator Operation and Maintenance Manual
Service Manual 72 pages · 5.5 MB · ZHThis manual provides installation, operation, calibration, configuration, and maintenance instructions for the Thermo Scientific 8000WJ Series water‑jacket…
Thermo Scientific Multiskan SkyHigh User Manual
User Manual 42 pages · 3.2 MB · ZHUser manual for the Thermo Scientific Multiskan SkyHigh plate reader, covering installation, operation, software use, safety and maintenance.
Thermo Scientific POPs Overall Analysis Workflow Product Leaflet
Product Leaflet 8 pages · 1.1 MB · ZHThermo Scientific’s POPs workflow combines TSQ Quantum XLS, DFS, TargetQuan software and LIMS for high‑throughput screening and confirmatory analysis.
Thermo Scientific AquaClear Low-Range Turbidity Analyzer Product Leaflet
Product Leaflet 50 pages · 2.8 MB · ZHThermo Scientific AquaClear low‑range turbidity analyzer product leaflet with specifications, features and ordering information.
Thermo Scientific PCR Plastics Selection Guide
Product Leaflet 26 pages · 3.9 MB · ENA guide that helps you choose the right Thermo Scientific PCR plates, tubes, and sealing options for optimal PCR and qPCR performance.
Thermo Scientific Orion Star A210 Desktop Meter User Manual
User Manual 123 pages · 3.2 MB · ZHThe Thermo Scientific Orion Star A210 desktop meter user manual provides setup, calibration, measurement, data logging, and troubleshooting instructions.
Thermo Scientific Heratherm 50129649 B Heating and Drying Oven Operation Manual
User Manual 140 pages · 12.9 MB · ENThe manual provides safety, installation, operation, maintenance and technical data for the Thermo Scientific Heratherm 50129649 B heating and drying oven.
Thermo Scientific TSQ Triple Quadrupole Mass Spectrometer Application Manual
Application Note 56 pages · 3.6 MB · ZHThis application manual explains how Thermo Scientific TSQ triple quadrupole mass spectrometers are used for food safety testing, covering pesticide…
Thermo Scientific 2D Labtainer BioProcess Container Data Sheet
Datasheet 7 pages · 340 KB · ENThermo Scientific 2D Labtainer BioProcess Containers are small‑volume liquid handling systems with specifications, configurations, and ordering details.
Thermo Scientific TSQ Quantum Access MAX Triple Quadrupole LC/MS Product Brochure
Product Leaflet 8 pages · 1.2 MB · ZHThe Thermo Scientific TSQ Quantum Access MAX triple quadrupole LC/MS offers fast polarity switching, zero‑memory collision cell and QED‑MS/MS for…
Thermo Scientific TransformAid Bacterial Transformation Kit User Manual
User Manual 2 pages · 308 KB · ENThe Thermo Scientific TransformAid Bacterial Transformation Kit User Manual provides protocols, storage instructions, and troubleshooting for rapid…
Thermo Scientific Evolution 201 & 220 UV-Vis Spectrophotometer User Manual
User Manual 14 pages · 1.7 MB · ZHThermo Scientific Evolution 201 & 220 UV‑Vis spectrophotometer manual with operation, software, accessories and specifications.
Thermo Scientific EDC 22980, 22981, 77149 Product Manual
User Manual 4 pages · 275 KB · ENThe Thermo Scientific EDC manual provides storage guidelines, coupling protocols, and two‑step reaction procedures for product numbers 22980, 22981, and 77149.
Thermo Scientific picoSpin 45/80 NMR Spectroscopy Teaching Plan
User Manual 44 pages · 4.3 MB · ZHTeaching plan with safety guidelines, experimental procedures and data analysis for Thermo Scientific picoSpin 45/80 NMR spectrometers.
Thermo Scientific CryoMed Controlled-Rate Freezers Product Catalog
Product Leaflet 36 pages · 2.8 MB · ENA catalog of Thermo Scientific CryoMed controlled-rate freezers, models, specifications, and accessories.
Which document do I need?
Service Manual
Disassembly, diagnostics and part numbers, for repair.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Application Note
How to use the product for one specific task, with worked examples.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Quick Start Guide
The shortest path to a working setup, usually only a few pages.
Questions answered in Thermo Scientific manuals
How can I level the incubator after installation?
Place a bubble level on the shelf, adjust the hex nuts on the leveling feet to raise or lower each side until the level indicates the unit is horizontal.
From: Thermo Scientific 8000WJ Series CO2 Incubator Operation and Maintenance Manual
What are the recommended operating temperature and humidity conditions?
The instrument operates from +10 °C to +40 °C. Relative humidity may be up to 80 % when the temperature is ≤31 °C and decreases linearly to 50 % at 40 °C.
What power supply does the Multiskan SkyHigh require and how much power does it use?
It accepts a 100‑240 V AC, 50/60 Hz supply. Maximum power draw is 110 W, typical operation uses less than 27 W, and in energy‑saving mode it uses under 10 W.
What is the measurement range of the AquaClear low‑range turbidity analyzer?
It measures turbidity from 0 to 100 NTU.
From: Thermo Scientific AquaClear Low-Range Turbidity Analyzer Product Leaflet
How many analog output channels does the AquaClear provide?
The instrument provides two analog output channels, each 4–20 mA.
From: Thermo Scientific AquaClear Low-Range Turbidity Analyzer Product Leaflet
What is the operating temperature range of the Orion Star A210?
The instrument operates between 5 °C and 45 °C.
From: Thermo Scientific Orion Star A210 Desktop Meter User Manual