Thermo Scientific EDC 22980, 22981, 77149 Product Manual

The Thermo Scientific EDC manual provides storage guidelines, coupling protocols, and two‑step reaction procedures for product numbers 22980, 22981, and 77149.


Thermo Scientific EDC 22980, 22981, 77149 Product Manual - cover page
Brand
Thermo Scientific
Category
Other
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
275 KB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
1A780CE0901ADF9512AD6FD56F934236

About this manual

This manual describes EDC (1‑Ethyl‑3‑[3‑Dimethylaminopropyl] Carbodiimide Hydrochloride), a zero‑length cross‑linker used to join carboxyl and amine groups. It includes product descriptions, molecular weight, CAS number, and recommended storage conditions for each product variant.

The document outlines single‑step coupling procedures, a two‑step EDC/NHS (or thiol‑NHS) coupling workflow, required reagents and buffers, quenching steps, purification using Zeba desalting columns, and storage of the final conjugates. Technical tips, related Thermo Scientific products, and warranty information are also provided.

What's inside

  • Product Description
  • Storage
  • Single‑step Coupling Procedure
  • Two‑step Coupling Procedure
  • Materials Required
  • Quenching and Purification
  • Technical Tips
  • References
  • Warranty

Specifications

Molecular weight191.7
CAS number25952-53-8
Product 22980 amount5 g
Product 22981 amount25 g
Product 77149 amount10 mg

Frequently asked questions

How should product 22980 be stored?

Product 22980 should be stored dry at –20 °C after receipt.

How long should the single‑step EDC coupling reaction be incubated at room temperature?

Incubate the reaction at room temperature for 2 hours.

Which reagent can be used to quench excess EDC after the first step of the two‑step coupling?

2‑Mercaptoethanol (2‑硫基乙醇) can be added to quench excess EDC.