ITT Conoflow GT210 Series Transducers Product Safety Alert
This document is a Product Safety Alert issued by ITT Enidine concerning the GT210 Series Transducers. It warns that when these transducers are used with certain intrinsic safety barriers in Class I, Division 1, Groups C and D hazardous locations, the energy limits for intrinsic safety may be exceeded. This could potentially ignite flammable gases if a coil failure generates a spark discharge exceeding safe energy levels.
| Affected Models | GT210, GT21R, GT410, GT41R, GT610, GT61R, GT810, GT81R |
|---|---|
| Hazardous Location Groups | Class I, Division 1, Groups C and D |
| Control Drawing Reference | 6385547 |
The energy released during a spark discharge in the event of a coil failure may surpass the energy level limits for intrinsic safety for Groups C and D, potentially igniting flammable gases.
By installing a suitable intrinsic safety barrier on the 4-20 mA control signal wiring in accordance with Control Drawing 6385547.
The notification was issued by ITT Enidine.