Emerson Figure 221/222 Butterfly Valves Installation and Maintenance Instructions

This document introduces the installation and maintenance instructions for Keystone Figure 221/222 butterfly valves.


Emerson Figure 221/222 Butterfly Valves Installation and Maintenance Instructions - cover page
Brand
Emerson
Category
Industrial Supply
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
895 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
AB0674725A12D8CD066480C4CC1DB4D7

About this manual

The Keystone Figure 221/222 is a rubber-lined butterfly valve with a maximum working pressure of 16 bar and a temperature range of -29°C to +120°C, depending on seat material. These instructions cover flange and pipeline compatibility, safety information, installation in new and existing systems, maintenance, and troubleshooting.

The valve is bi-directional and installs between ANSI Class 125/150 flat or raised face flanges without gaskets. Routine maintenance or lubrication is not required.

What's inside

  • Introduction
  • Flange and pipeline compatibility
  • Safety related information
  • Installation in pipeline
  • Maintenance
  • Installation in an existing system
  • Installation in a new system
  • Troubleshooting

Specifications

Maximum working pressure16 bar
Temperature range-29°C to +120°C
Flange compatibilityANSI Class 125/150 flat or raised face flanges
Seat shelf life5 years

Frequently asked questions

What is the maximum working pressure of the Figure 221/222 valve?

The maximum working pressure is 16 bar, depending on seat material.

Are flange gaskets required when installing the valve?

No, gaskets are not required because the Keystone seat face design eliminates the need for them.

Can the valve be installed in any pipeline orientation?

Yes, the valves are bi-directional and can be installed in vertical, horizontal, or intermediate orientations.

What should be done if the valve opens only a few degrees?

Loosen the flange bolts, re-align the valve with the flanges, and re-tighten the flange bolts to the correct torque per ANSI requirements.