Toshiba TOSVERT VF-AS1 Series Industrial Inverter RS485 Communication Function Operation Manual

TOSVERT VF-AS1 series RS485 communication function operation manual, introduces the RS485 communication function of variable frequency drive, including communication port, communication protocol, communication command, communication parameters, computer command and monitoring and other contents.


Toshiba TOSVERT VF-AS1 Series Industrial Inverter RS485 Communication Function Operation Manual - cover page
Brand
Toshiba
Category
inverter
Document type
Programming Manual
Language
Chinese
Pages
96
File format
PDF
File size
1.5 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
6320904A6F9F29E73277700B9002C71E

About this manual

This Chinese manual describes the RS485 communication function of the Toshiba TOSVERT VF-AS1 Series industrial inverter. It covers the standard 2-wire and 4-wire RS485 ports, computer link operation, and inter-drive communication without a computer.

The document explains data transmission specifications and frame handling, then details the Toshiba inverter protocol and MODBUS-RTU protocol, including ASCII and binary formats, commands, broadcast communication, and error codes. It also covers communication parameters, computer commands and monitoring, parameter data, and appendices for data codes, response time, VF-A7 compatibility, troubleshooting, and RS485 wiring. This manual is written in Chinese.

What's inside

  • Communication Function Overview
  • Data Transmission Specifications
  • Communication Protocol
  • Toshiba Inverter Communication Protocol
  • MODBUS-RTU Protocol
  • Inter-drive Communication
  • Communication Parameters
  • Computer Commands and Monitoring
  • Parameter Data
  • RS485 Communication Wiring

Specifications

Communication baud rate9600 / 19200 / 38400 bps; selectable with a parameter
Communication protocolToshiba inverter protocol / MODBUS-RTU; selectable with a parameter
Character transmission (ASCII mode)JIS X 0201 8-bit (ASCII)
Character transmission (binary / MODBUS-RTU)Fixed 8-bit binary code
Stop bit lengthInverter receive: 1 bit; inverter send: 2 bits
ParityEven / odd / none; selectable with a parameter
Checksum / CRCChecksum for Toshiba inverter protocol; CRC for MODBUS-RTU
Frame lengthVariable, up to 17 bytes
Bit transmission orderLow-order bit first

Frequently asked questions

Which communication protocols are supported?

The manual lists the Toshiba inverter protocol and MODBUS-RTU; it notes that MODBUS-RTU does not support all commands.

What baud rates can be selected?

9600, 19200, or 38400 bps can be selected with a parameter.

How soon after power-on can communication begin?

Communication can begin after about two seconds of setting initialization.

What is the maximum frame length?

The frame length is variable and can be up to 17 bytes.

Download PDF (1.5 MB)

More Toshiba Manuals