Toshiba TM VF-AS1 Series Inverter Operation Manual
This document is the instruction manual for the new high-performance inverter, model TOSVERT TM VF-AS1. It covers 200V class units from 0.4kW to 75kW and 400V class units from 0.75kW to 500kW.
Read onlineToshiba VF-AS1 Series specifications
| Communication baud rate | 9600 / 19200 / 38400 bps; selectable with a parameter |
|---|---|
| Communication protocol | Toshiba inverter protocol / MODBUS-RTU; selectable with a parameter |
| Character transmission (ASCII mode) | JIS X 0201 8-bit (ASCII) |
| Character transmission (binary / MODBUS-RTU) | Fixed 8-bit binary code |
| Stop bit length | Inverter receive: 1 bit; inverter send: 2 bits |
| Parity | Even / odd / none; selectable with a parameter |
| Checksum / CRC | Checksum for Toshiba inverter protocol; CRC for MODBUS-RTU |
| Frame length | Variable, up to 17 bytes |
| Bit transmission order | Low-order bit first |
Source: Toshiba TOSVERT VF-AS1 Series Industrial Inverter RS485 Communication Function Operation Manual
All Toshiba VF-AS1 Series documents by type
Instruction set, parameters and examples for configuring or programming the device.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Which communication protocols are supported?
The manual lists the Toshiba inverter protocol and MODBUS-RTU; it notes that MODBUS-RTU does not support all commands.
From: Toshiba TOSVERT VF-AS1 Series Industrial Inverter RS485 Communication Function Operation Manual
What baud rates can be selected?
9600, 19200, or 38400 bps can be selected with a parameter.
From: Toshiba TOSVERT VF-AS1 Series Industrial Inverter RS485 Communication Function Operation Manual
Which communication protocols are supported by the VF-AS1 series?
The inverter supports the TOSHIBA Inverter Protocol and the MODBUS-RTU Protocol.
From: Toshiba VF-AS1 Series RS485 Communication Function Instruction Manual
What is the default communication protocol setting?
The initial value for the communication protocol selection parameter is set to 0, which corresponds to the TOSHIBA protocol.
From: Toshiba VF-AS1 Series RS485 Communication Function Instruction Manual
What is the rated power range for the 200V class inverter?
The 200V class model covers a power range from 0.4kW to 75kW.
What is the rated power range for the 400V class inverter?
The 400V class model covers a power range from 0.75kW to 500kW.