Honeywell UDC3300 Process Controller User Manual

This manual introduces the Chinese operation method of Honeywell UDC3300 process controller, including panel display screen description, keyboard function introduction, configuration submenu, loop 1 parameter tuning, loop 2 parameter tuning, set point slope/set point programming, adaptive adjustment setting, control algorithm setting, output algorithm, input 1, input 2, input 3, loop 1 control, loop 2 control, options, communication, alarm settings, display settings, calibration, backup manual operation, etc.


Honeywell UDC3300 Process Controller User Manual - cover page
Brand
Honeywell
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
30
File format
PDF
File size
317 KB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
367ED584CBA92EB45DB32A6F662E1AB1

About this manual

This document serves as the Chinese operation manual for the Honeywell UDC3300 process controller. It provides detailed instructions on using the device's panel display and keyboard functions, including how to switch between manual and automatic modes and navigate configuration groups.

The manual extensively covers the configuration sub-menus, detailing settings for Loop 1 and Loop 2 tuning (PID parameters), setpoint ramping and programming, adaptive tuning (Accutune), control algorithms, input configurations, and alarm setup. It also includes information on communications settings and calibration procedures. This manual is written in Chinese.

What's inside

  • Panel Display Explanation
  • Keyboard Function Introduction
  • Configuration Sub-menus
  • Loop 1 and Loop 2 Tuning
  • Setpoint Ramp and Programming
  • Accutune Adaptive Tuning
  • Control Algorithm Settings
  • Input and Output Configuration
  • Alarm Settings
  • Communications Settings

Specifications

PID Parameter Range (Gain)0.001 ~ 1000
Derivative Time Range0.00 ~ 10.00 minutes
Integral Time Range0.02 ~ 50.00 minutes
Setpoint Ramp Time Range0 ~ 255 minutes
Communication Baud Rate300, 600, 1200, 2400, 4800, 9600, 19200

Frequently asked questions

How do I switch between manual and automatic control modes?

Press the MANUAL/AUTO key to alternately select manual or automatic control modes.

What is the range for the PID Gain parameter?

The PID Gain parameter can be set between 0.001 and 1000.

Can the controller be locked to prevent configuration changes?

Yes, the LOCKOUT function allows you to lock configuration, calibration, or monitoring modes.