Rosemount 0065/0185 Sensor Assembly Quick Start Guide
This guide provides basic installation guidelines for Rosemount 0065 and 0185 sensor assemblies. It includes wiring diagrams, sensor dimensions, and specifications for RTD and thermocouple sensors. Safety warnings and physical security recommendations are included. The guide does not cover configuration, diagnostics, or hazardous location installations.
| RTD Resistance | 100 Ω at 0 °C |
|---|---|
| Temperature Range | 50 to 450 °C (-58 to 842 °F) or -196 to 300 °C (-321 to 572 °F) |
| Thermal Response Time | Nine seconds maximum to reach 50 percent sensor response |
| Insulation Resistance | 1,000 MΩ minimum |
| Sheath Material | 316 SST sensor tip with 321SST mineral insulated cable |
For 3-wire systems, use one white and two red leads. Do not connect the white leads. For 2-wire systems, connect both sets of leads.
The Rosemount connection head is rated to IP66/IP68 and NEMA® 4X. The BUZ and BUZH connection heads are rated to IP65.