This manual provides instructions for installing high-performance butterfly valves and includes tips for checking the valve before and after installation.
This manual covers the installation, operation, and maintenance of the Emerson Keystone K-LOKe 36 and 37 series high-performance butterfly valves. It details specific installation directions, including recommendations for stem orientation and sealing surfaces, as well as warnings regarding temperature limits and pressure relief during disassembly.
The document provides step-by-step procedures for installing the valve in various configurations (wafer, lug, and double flange), performing routine maintenance on the packing gland, and conducting major disassembly for repair. It also includes a comprehensive list of standard construction materials and their corresponding ASTM standards for valve components. This manual is written in Chinese.
| Temperature Limit | 200*C [392F] |
|---|---|
| Recommended Stem Orientation | Horizontal or tilted from vertical |
| Seal Facing Direction | Upstream when closed |
| Packing Gland Torque Warning | Do not over-tighten |
The valve should be installed with the stem horizontal or tilted from vertical, unless specified otherwise. The arrow on the valve body indicates the recommended direction.
The valve must be insulated when the medium temperature exceeds 200*C [392F].
If leakage is detected, tighten the packing gland nut in half-turn increments until the leak stops, but do not over-tighten.