The manual provides installation instructions for the Micro Motion 5700 series transmitters, including electrical connections, mechanical installations, and safety connections.
This Installation Manual provides instructions for planning, mounting, and wiring Micro Motion 5700 transmitters with configurable inputs and outputs. It covers all installation types, including integral, four-wire, and nine-wire configurations. The document assumes users understand basic transmitter and sensor installation concepts.
| Maximum cable length | 1,000 ft (305 m) |
|---|---|
| Cable type for connections | Shielded, twisted-pair instrument cable with drain |
| Cable type for RS-485 | Twisted-pair shielded cable |
| Wire size for 5700 to 3100 connection | 24 AWG (0.25 mm²) to 16 AWG (1.5 mm²) |
The maximum cable length should not exceed 1,000 ft (305 m).
A shielded, twisted-pair instrument cable with drain is required.
Use wire size 24 AWG (0.25 mm²) to 16 AWG (1.5 mm²).