Emerson Micro Motion 5700 Transmitters Installation Manual

The manual provides installation instructions for the Micro Motion 5700 series transmitters, including electrical connections, mechanical installations, and safety connections.


Emerson Micro Motion 5700 Transmitters Installation Manual - cover page
Brand
Emerson
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
56
File format
PDF
File size
5.1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
D8316EF6FF16158E43776D87C4AE0DB4

About this manual

This Installation Manual provides instructions for planning, mounting, and wiring Micro Motion 5700 transmitters with configurable inputs and outputs. It covers all installation types, including integral, four-wire, and nine-wire configurations. The document assumes users understand basic transmitter and sensor installation concepts.

What's inside

  • Before you begin
  • Planning
  • Mounting and Sensor Wiring
  • Wiring the channels
  • Wiring the power supply
  • Configuring the transmitter
  • Using the display controls
  • Service port connection

Specifications

Maximum cable length1,000 ft (305 m)
Cable type for connectionsShielded, twisted-pair instrument cable with drain
Cable type for RS-485Twisted-pair shielded cable
Wire size for 5700 to 3100 connection24 AWG (0.25 mm²) to 16 AWG (1.5 mm²)

Frequently asked questions

What is the maximum cable length for wiring between the transmitter and sensor?

The maximum cable length should not exceed 1,000 ft (305 m).

What type of cable is required for all in and out connections?

A shielded, twisted-pair instrument cable with drain is required.

What wire size is recommended for connecting the Micro Motion 5700 to the Micro Motion 3100 transmitter?

Use wire size 24 AWG (0.25 mm²) to 16 AWG (1.5 mm²).