Model 3293A is a low-noise, high sensitivity, miniature LIVM triaxial accelerometer featuring a single, transverse mounted, 4- pin electrical connector. This feature allows the 3293A to be used in situations where vertical space is limited.
The Dytran Model 3293A is a low-noise, high-sensitivity miniature triaxial LIVM accelerometer featuring a single 4-pin connector and case grounding. It utilizes ceramic shear technology with built-in amplifiers to allow operation with simple constant current power units and long cables. The device measures complete motion of a point using three orthogonally mounted elements within a titanium housing.
| Weight | 8.8 grams |
|---|---|
| Size | 0.55 x .37 x .89 inches |
| Mounting | 5-40 UNF internal thread |
| Connector | 4-Pin |
| Material | Titanium Alloy |
| Sensitivity | 500 mV/g |
| Range | +7 g |
| Frequency Response | 0.25 to 4000 Hz |
| Phase Response | 1 to 3000 Hz |
| Element Natural Frequency | >15 kHz |
| Electrical Noise Floor | -0002 grms |
| Linearity | 1 % FS |
| Transverse Sensitivity | 6 % |
| Supply Current Range | 2 to 20 mA |
| Compliance Voltage Range | +18 to +30 VDC |
| Output Impedance | 150 Ohms |
| Output Bias Voltage | +11 10 +13 VDC |
| Discharge Time Constant | 1.0 to 1.5 sec |
| Ground Isolation | Case Grounded |
No, this instrument is not field repairable and no maintenance is required or possible.
Yes, the 3293A may be operated with standard IEPE signal conditioners.
The internal amplifier will be immediately destroyed.