This document is the instruction manual for Anderson Greenwood valves, which introduces how to install, operate and maintain valves
This document serves as the Installation, Operation, and Maintenance Instructions for Anderson Greenwood instrumentation products, including hand valves, gauge valves, manifolds, and ball valves with bore sizes of 25mm (1") or less. It outlines safety precautions, installation procedures for various connection types, and specific operational guidelines for multi-turn rising stem and ball valves.
| Product Coverage | Hand Valves, gauge valves, manifolds and accessories with multi-turn-rising stem; Ball valve products with bore sizes of 25mm (1") or less |
|---|---|
| Stem Thread Direction | Right hand thread |
| Operating Direction | Counter-clockwise to open and clockwise to close |
They should be stored in the original delivery crates with any waterproof lining and/or desiccant remaining in place, off the ground in a clean, dry, indoor area.
Bolts should be tightened in a diagonal pattern.