This is a manual about Emerson Electrochemical H2S Detector. It introduces the features and usage of the product.
The Net Safety Monitoring Inc. H2S-X X X -X X electrochemical Hydrogen Sulfide (H2S) gas detector consists of an explosion-proof enclosure, electronic circuitry and an electrochemical H2S sensing element. The detector can be used with one of the Net Safety Monitoring Inc. Uni-Trol™ Controllers or with other devices that are capable of monitoring a 4 to 20 mA dc input.
| Operating Range | 0 to 100 ppm (Optional: 50, 20, or 10 ppm) |
|---|---|
| Drift | Less than 2 ppm per month |
| Accuracy | ±10 percent of applied gas concentration or ±3 ppm, whichever is greater |
| Sensor Life | 2 to 4 years |
| Operating Voltage | 10 to 32Vdc (24Vdc nominal) |
| Temperature Range (Operation) | -40 °F to 122 °F (-40 °C to 50 °C) |
| Humidity Range | 15 to 90% RH, non-condensing |
Sensors and detectors are warranted against defective parts and workmanship for 24 months from the date of purchase.
Other electronic assemblies are warranted for 36 months from the date of purchase.
Yes, the explosion-proof detector is CSA certified for use in hazardous locations (Class 1, Division 1, Groups C & D).