ROHM TO-247-4L Half-Bridge Evaluation Board Operation Manual

This document is the ROHM TO-247-4L Half-Bridge Evaluation Board Operation Manual, which mainly introduces the product features, usage and precautions of the evaluation board


ROHM TO-247-4L Half-Bridge Evaluation Board Operation Manual - cover page
Brand
ROHM
Document type
User Manual
Language
English
Pages
41
File format
PDF
File size
4.7 MB
Published
13 October, 2023
Updated
13 October, 2023
MD5 checksum
0557EABF7820B98A927E0536BFF41451

About this manual

The document serves as an operation guide for the TO-247-4L Half-Bridge Evaluation Board, specifically designed for SiC MOSFETs. It details the necessary external power sources and input signals required to avoid malfunctions, emphasizing strict adherence to specific power ON and OFF sequences.

Key operational features include several LED indicators that display the status of high voltage (HV), control power (+5V), isolated gate drive power, and various fault conditions such as HS/LS failures and over-current protection (OCP). The manual explains how these LEDs function and describes procedures for resetting latch conditions using a dedicated push-button switch.

What's inside

  • Safety Precautions
  • LED Indicators
  • Fault Status Details
  • Over Current Protection (OCP)
  • OCP Setting at Zero Bias
  • OCP Setting at Negative Bias

Frequently asked questions

What happens if the Alarm LED turns ON?

The board goes into a Latch condition due to an external circuit fault, but it can be cleared by pushing the Reset button.

How do you reset an OCP latch?

After clearing the abnormal condition causing the Over Current Protection (OCP), push the Reset switch (SW301) to turn OFF the OCP LED.

What voltage level turns on the OCP LED during negative bias adjustment?

The LED for OCP turns ON when the measured voltage at TP303 is around -0.65V.