Flowline UGO6 & UG12 Series Ultrasonic Level Transmitter User Manual

This manual describes the features and use of Flowline's EchoPod® ultrasonic level transmitter.


Flowline UGO6 & UG12 Series Ultrasonic Level Transmitter User Manual - cover page
Brand
FlowLine
Category
Other Electronics
Document type
User Manual
Language
English
Pages
52
File format
PDF
File size
2.2 MB
Published
12 October, 2023
Updated
12 October, 2023
Model
UG12
MD5 checksum
F140BD8B38AF62760231C60D3EA3EC29

About this manual

This manual provides instructions for the Flowline EchoPod® UGO6 and UG12 series ultrasonic level transmitters. It explains the reflective ultrasonic technology used to measure liquid levels by calculating the time of flight for sound waves reflected from the process medium. The document details the device's features, including its ability to operate in high-temperature environments and its vertical mounting design to prevent condensation interference.

What's inside

  • Introduction
  • Specifications
  • Mounting Guide
  • Sensor Configuration
  • Wiring and Electrical
  • Installation
  • Factory Settings
  • Troubleshooting

Specifications

UG12 Range12.0m (39.4 feet)
UGO6 Dead band20cm (8 inches)
UG12 Dead band45.7cm (18 inches)

Frequently asked questions

How do I configure the sensor?

You can configure the sensor using either the WebCal® software or the Push Button Display.

What materials are the enclosure and transducer made of?

The enclosure is made of Polypropylene (PP) and the transducer is made of Polyvinylidene Fluoride (PVDF).

Can the EchoPod be used in hazardous environments?

No, the EchoPod® should not be used within classified hazardous environments.