This is a manual for a liquid level switch, including information about the product's length, installation position, pressure, temperature, etc.
This manual provides instructions for the Flowline Switch-Pak with Compact Junction Box, specifically the AU18, AV16, and AZ18 series. These units are single-point mounting systems designed to install one level sensor vertically within a tank using ultrasonic, buoyancy, or vibration technologies.
| Length | 6" to 10' (15 cm to 3m) |
|---|---|
| Process Temperature | -40˚ to 176˚ F (-40˚ to 80˚ C) |
| Pressure (AU1/AZ1) | 150 psi (10 bar) |
| Pressure (AV1) | 25 psi (1.7 bar) |
| Enclosure Rating | NEMA 4X (IP65) |
| Supply Voltage (Ultrasonic) | 12-36 VDC |
| Supply Voltage (Vibration) | 12-30 VDC |
| Wetted Material (PP) | Polypropylene |
| Wetted Material (PVDF) | Polyvinylidene Fluoride |
The technologies used are Ultrasonic, Buoyancy, or Vibration.
Connect the Red wire to Positive (+) and the Black wire to Negative (-). Attach the load to either the Green or White wires.
Disconnect power, remove the sensor, wash it with a soft bristle brush and mild detergent, and reinstall it.