About this manual

This manual provides installation instructions and operating procedures for the Pentair IntelliBrite Controller. The device controls Pentair Water Pool and Spa IntelliBrite underwater LED lights and landscape lights, allowing users to select pre-programmed color light shows or fixed colors via a dial interface.

The guide covers safety precautions regarding electrical shock and grounding requirements, kit contents verification, outlet box specifications, and step-by-step wiring instructions for connecting the controller to 12 VAC IntelliBrite LED pool/spa lights and landscape lights. It also explains how to use the Hold and Recall buttons to create custom lighting effects.

What's inside

  • IntelliBrite Controller Overview
  • Controls and Buttons
  • Selecting a Light Show or Fixed Color
  • Hold and Recall Feature
  • Powering on the IntelliBrite light(s)
  • Troubleshooting
  • Outlet Box Specifications
  • Installing an Outlet box for the IntelliBrite Controller
  • Wiring an IntelliBrite Controller to IntelliBrite LED Lights

Specifications

Input Voltage120 VAC
Outlet Box Volume22.5 cubic inches minimum
Conduit Size3/4 inch steel conduit
Mounting Height1 foot above water level

Frequently asked questions

Can I connect pool lights directly to the controller?

No, you must use an appropriate step-down transformer between the controller and the 12 VAC IntelliBrite LED lights.

What is the minimum distance from water for installation?

The controller must be installed at least 5 feet (3 meters for Canadian installations) away from any body of water.

What safety device is required for the lighting circuit?

The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) and an appropriately rated circuit breaker.