This manual describes the automation and chlorination functions of the AQL-PS-4, AQL-PS-8-V, AQL-PS-8, AQL-PS-16-V, and AQL-PS-16 water treatment devices.
The document is an operation manual for the Goldline Controls Aqua Logic series of multifunction pool and spa controllers. It details how to use the device to manage pumps, valves, lighting, heaters, and chlorination systems in both manual and automatic modes.
Key topics include adjusting water chemistry parameters such as free chlorine, pH, alkalinity, salt levels, and calcium hardness. The guide also covers system maintenance procedures like servicing the electrolytic cell, winterizing the equipment, and troubleshooting common issues using diagnostic menus.
| Controlled Equipment Capacity (PS-4) | up to 4 high voltage pieces of equipment |
|---|---|
| Controlled Equipment Capacity (PS-8) | up to 8 high voltage pieces of equipment |
| Controlled Equipment Capacity (PS-16) | up to 16 high voltage pieces of equipment |
| Valve Actuators Capacity (PS-4) | up to 4 automatic valve actuators |
| Heater Capacity | 2 conventional heaters plus a solar heater |
The manual indicates an ideal range of 1.0 - 3.0 ppm.
Turn the output dial up to increase pH and down to decrease it, targeting a range of 7.2 - 7.6.
The ideal range for alkalinity is between 80 and 120 ppm.