The Agilent 1260 Infinity Fraction Collector is designed for optimized fraction collection in laboratories performing semiprepartive to preparative-scale purification with typical flow rates from 2 to 100 mL/min. It has been engineered to fit in the modular design of the Agilent 1200 Infinity LC family, occupying a minimum of benchspace and facilitating short tubing connections for minimized peak dispersion.


Agilent 1260 Infinity Preparative-Scale Fraction Collector Handbook - cover page
Brand
Agilent
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
81 KB
Published
04 July, 2012
Updated
30 September, 2023
MD5 checksum
E9CA58883895C4301EEEF00BE8CFD38F

About this manual

The handbook describes the Agilent 1260 Infinity Preparative-Scale Fraction Collector, which is designed for semipreparative to preparative‑scale purification with typical flow rates from 2 to 100 mL/min. It highlights low delay volumes, a unique delay sensor, multiple collection modes, and a variety of tray and container options, as well as GLP and 21 CFR Part 11 compliance features.

Technical details include the lowest delay volume of approximately 500 µL, a maximum system flow of 100 mL/min, support for up to three collectors in parallel, and environmental limits of 4 – 55 °C with less than 95 % non‑condensing humidity. Ordering information and part numbers for trays, tubes, and accessories are also provided.

What's inside

  • Features
  • Technical Details
  • Lowest delay volume
  • Unique delay sensor
  • Multiple collection modes
  • Fraction collection containers
  • Various collection strategies
  • Specifications
  • Ordering Details

Specifications

Delay volume (preparative)Approximately 500 µL
Maximum system flow100 mL/min
Operating environment4 – 55 °C, < 95 % humidity
Supported fraction containers96 deep‑well plates, test tubes up to 100 mm, autosampler vials (2 mL & 6 mL), Eppendorf safe‑lock tubes

Frequently asked questions

What is the typical flow‑rate range for the 1260 Infinity Preparative‑Scale Fraction Collector?

Typical flow rates are from 2 to 100 mL/min.

How many fraction collectors can be connected in parallel?

Up to three fraction collectors can be connected in parallel.

What types of collection containers are supported?

The collector supports deep‑well plates, test tubes up to 100 mm height, autosampler vials, and Eppendorf safe‑lock tubes.