This document provides operating instructions for the Ideal 61-734, a 400 Amp Clamp Meter from the 730 Series. The device features a dynamic range of 4,000 counts, a data hold switch for easy reading in dimly lit locations, and a sleep function to extend battery life. It is designed with safety features conforming to IEC61010 standards, including shrouded transformer jaws and overvoltage protection categories up to 600V. The manual includes detailed safety warnings and step-by-step guides for measuring AC current, AC voltage, DC voltage, and resistance.
| Measuring Range (AC Current) | 400A (0-399.9A) |
|---|---|
| Measuring Range (DC Voltage) | 600V |
| Measuring Range (Resistance) | 40000 Ohms (150-3909 Ohms) |
| Display | Liquid crystal display (maximum count: 3999) |
| Response Time | Approx. 2 seconds |
| Sample Rate | About 2.5 times per second |
| Power Source | Two R03 or equivalent (DC1.5V) batteries |
| Dimensions | 184(L) x 44(W) x 27(D)mm |
| Weight | Approx. 19g (including batteries) |
The maximum measuring range for AC current is 400A (0-399.9A).
The meter requires two R03 or equivalent (DC1.5V) batteries.
The maximum conductor size is approximately 30mm in diameter.