Agilent 710-ES ICP-OES Application Note for Heavy Metal Monitoring

This application note describes a method for monitoring heavy metals using ICP-OES to ensure compliance with RoHS and WEEE directives.


Agilent 710-ES ICP-OES Application Note for Heavy Metal Monitoring - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
6
File format
PDF
File size
45 KB
Published
12 June, 2012
Updated
30 September, 2023
Model
710-ES
MD5 checksum
363A9D57F77A563AA60EDD7EBAA1BA1C

About this manual

The document discusses the European Union's RoHS and WEEE Directives regarding hazardous substances in electrical and electronic equipment. It identifies Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) as a suitable analytical technique for determining heavy metals like Cadmium, Lead, Chromium, and Mercury.

The text details the operating parameters of an Agilent 710-ES axial ICP-OES instrument equipped with an echelle polychromator and megapixel CCD detector. It further evaluates various sample preparation methods—specifically comparing EN 1122, HNO3/H2O2 digestion, and EPA Method 3051A microwave digestion—for analyzing heavy metals in plastic samples.

What's inside

  • Introduction
  • Instrumentation
  • Materials and Reagents
  • Sample Preparation
  • Results and Discussion
  • Detection Limits

Frequently asked questions

What is the maximum recommended heating temperature for decomposing plastic material?

The text states that a heating temperature of 95 °C is not high enough to decompose the plastic material.

What digestion method is required to achieve complete recovery of mercury?

Closed vessel microwave digestion is the only method to get complete recovery of Hg.

Download PDF (45 KB)

More Agilent Manuals


View all Agilent manuals →