Powerex C390_X555 Phase Control SCR Outline Drawing and Datasheet


Powerex C390_X555 Phase Control SCR Outline Drawing and Datasheet - cover page
Brand
Powerex
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
194 KB
Published
06 June, 2012
Updated
06 June, 2012
Model
X555
MD5 checksum
A90FF300284205A51D5FF3031B32D1AB

About this manual

This document provides an outline drawing with dimensional specifications in inches and millimeters for the Powerex C390_X555 device. It details the physical layout labeled A through T to assist with mechanical design and mounting.

The datasheet lists absolute maximum ratings, including RMS on-state current of 925 Amperes and average on-state current of 90 Amperes. It also covers electrical characteristics such as forward leakage, peak on-state voltage, switching times, and thermal resistance values for junction-to-case and case-to-sink configurations.

What's inside

  • Outline Drawing
  • Description
  • Features
  • Applications
  • Ordering Information
  • Absolute Maximum Ratings
  • Electrical Characteristics
  • Thermal Resistance

Specifications

Critical Rate-of-Rise of On-State Current (Repetitive)500 Amperes/us

Frequently asked questions

What is the maximum average on-state current for this device?

The maximum average on-state current is 590 Amperes.

What are the operating temperature limits for the C390_X555?

The device can operate between -40 and 150 degrees Celsius.

What is the maximum peak gate power dissipation allowed?

The maximum peak gate power dissipation is 200 Watts.