SCHURTER 4719 Power Entry Module Datasheet

The product is 1 POWER ENTRY MODULES WITHOUT LINE FILTER 44771199, with fuse holder and neon indicator, protection class I, with 5 x 20 mm 1-pole fuse, with soldered terminals 3.8 x 0.8 mm, with internal connections, except neon indicator to allow for different configurations. Neon indicator with wire terminals. Meets the requirements of medical standard IEC/EN 60601-1. The fuse drawer can only be opened with the aid of a tool. The fuseholder is accessible from the equipment front. Qualified for use in equipment according IEC/EN 60950.


SCHURTER 4719 Power Entry Module Datasheet - cover page
Brand
SCHURTER
Category
AC-DC Power
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
164 KB
Published
10 May, 2012
Updated
30 September, 2023
MD5 checksum
5378DCB93FED439961FCA26602E69E08

About this manual

The SCHURTER 4719 is a panel‑mount power entry module without a line filter, available in snap‑in versions with optional neon indicator. It features a 1‑pole fuseholder, tool‑only opening, and compliance with IEC/EN 60601‑1 and IEC/EN 60950 standards.

The document lists technical data such as IEC and UL/CSA ratings, dielectric strength, temperature range, IP protection class, material, panel thickness options, and various order numbers for different variants. Derating curves and diagrams illustrate performance under different ambient temperatures.

What's inside

  • Description Characteristics
  • Technical Data
  • Ratings
  • Dielectric Strength
  • Degree of Protection
  • Material
  • Panel Thickness
  • Dimensions
  • Diagrams
  • Derating curves

Specifications

IEC rating10 A / 250 VAC, 50 Hz
UL/CSA rating10 A / 250 VAC, 60 Hz
Dielectric strength2.5 kVAC between L‑N
Operating temperature range-25 °C to 70 °C
IP protection classIP 40
Panel thickness (snap‑in)1/1.2/1.5/2/2.5/3 mm
Housing materialThermoplastic, Black, UL 94V‑0
Fuseholder type1‑pole, Shocksafe PC2

Frequently asked questions

What is the operating temperature range of the SCHURTER 4719 module?

The allowable operation temperature is –25 °C to 70 °C.

What IP protection rating does the module have?

It has a front‑side protection class of IP 40 according to IEC 60529.

What are the IEC electrical ratings for the 4719?

The module is rated for 10 A at 250 VAC, 50 Hz under IEC standards.

What type of fuseholder is used in the 4719?

It uses a 1‑pole fuseholder classified as Shocksafe category PC2.

Download PDF (164 KB)

More SCHURTER Manuals