The X60008 series are high‑precision 4.096 V floating‑gate analog (FGA™) voltage references offered in three variants (B‑41, C‑41, D‑41). They provide very low supply current (500 nA typical) and excellent temperature stability, making them suitable for precision industrial, sensor and calibration applications.

The devices are supplied in an 8‑lead SOIC package, operate from 4.5 V to 9.0 V supply voltage, and are rated for a temperature range of –40 °C to +85 °C. Detailed electrical characteristics, typical performance curves, and application circuits are included in the datasheet.

What's inside

  • Description
  • Features
  • Applications
  • Package Diagram
  • Pin Configurations
  • Ordering Information
  • Absolute Maximum Ratings
  • Recommended Operating Conditions
  • Electrical Characteristics
  • Typical Performance Characteristic Curves

Specifications

Output Voltage4.096 V
Supply Current (typical)500 nA
Input Voltage Range4.5 V to 9.0 V
Temperature Coefficient (B/C)3 ppm/°C
Operating Temperature Range-40 °C to +85 °C
Package8‑lead SOIC

Frequently asked questions

What is the output voltage of the X60008 series?

The devices provide a fixed 4.096 V reference output.

How much supply current does the X60008 consume?

Typical supply current is 500 nA.

What temperature range can the X60008 operate in?

The parts are rated for –40 °C to +85 °C.

What is the allowed input voltage range?

The devices operate from 4.5 V up to 9.0 V.